airGR issueshttps://gitlab.irstea.fr/HYCAR-Hydro/airgr/-/issues2021-03-24T12:00:30+01:00https://gitlab.irstea.fr/HYCAR-Hydro/airgr/-/issues/100Unclear message when Qupstream is NA2021-03-24T12:00:30+01:00Thirel GuillaumeUnclear message when Qupstream is NAWhen we have NA in upstream discharge (observations), the error message is unclear.
For a run (I modified the following in the example `InputsModel$Qupstream[5000] <- NA`) :
```
OutputsModel <- RunModel_Lag(InputsModel = InputsModel,
...When we have NA in upstream discharge (observations), the error message is unclear.
For a run (I modified the following in the example `InputsModel$Qupstream[5000] <- NA`) :
```
OutputsModel <- RunModel_Lag(InputsModel = InputsModel,
+ RunOptions = RunOptions, Param = Lag)
Error in if (any(OutputsModel$Qsim < 0)) { :
valeur manquante là où TRUE / FALSE est requis
```
For a calibration (according to @cyril.thebault):
```
Grid-Screening in progress(0%Error in FUN_MOD(InputsModel, RunOptions = RunOptions, Param = Param[iFirstParamRunOffModel:length(Param)]):
NA/NaN/Inf in foreign function call (arg2)
```
@olivier.delaigue and @david.dorchies, I think we need to better check NAs. In my opinion, NAs should be forbidden, such as are NAs for P and T.v1.6.11https://gitlab.irstea.fr/HYCAR-Hydro/airgr/-/issues/77Warn users in SeriesAggreg when ConvertFun is not provided2021-01-06T10:07:56+01:00Delaigue OlivierWarn users in SeriesAggreg when ConvertFun is not providedIt may be a good idea to return a message when `SeriesAggreg()` is applied on a unknown object (e.g. not `InputsModel ` or `OutputsModel` objects) and `ConvertFun` is also not provided.It may be a good idea to return a message when `SeriesAggreg()` is applied on a unknown object (e.g. not `InputsModel ` or `OutputsModel` objects) and `ConvertFun` is also not provided.v1.6.10