Commit daeb10be authored by Delaigue Olivier's avatar Delaigue Olivier
Browse files

docs(man): add explanation about the use of GR5H in the 'Details' section of the PrepGR function

Refs #41
parent 62640f1b
Pipeline #25355 passed with stage
in 2 minutes and 11 seconds
......@@ -63,7 +63,9 @@ function
\details{
If the \code{ObsDF} argument is provided, \code{DatesR}, \code{Precip}, \code{PotEvap}, \code{Qobs} and \code{TempMean} are not necessary, and vice-versa. If one variable is provided in \code{ObsDF} and also separately, then only the data included in \code{ObsDF} are used.
\cr \cr
\cr\cr
If \code{HydroModel = "GR5H"}, by default, this model is used without the interception store (i.e. without specifying \code{Imax}; see \code{\link[airGR]{RunModel_GR5H}}).
\cr\cr
If the \code{CemaNeige} argument is set to \code{TRUE}, the default version of CemaNeige is used (i.e. without the Linear Hysteresis, see the details part in \code{\link[airGR]{CreateRunOptions}}).
\cr\cr
The \code{PrepGR} function can be used even if no observed discharges are available. In this case, it is necessary to provide observed discharges time series equal to NA: this means that either the \code{ObsDF} observed discharges column or the \code{Qobs} arguments, depending on the format of data you provide, must be provided and filled with NAs.
......