diff --git a/configs/config_mb_2023_3_mux_2024.py b/configs/config_mb_2023_3_mux_2024.py
new file mode 100644
index 0000000000000000000000000000000000000000..3b0e8cad1e2ff6f1f1387b5e20ec4ddaa58ff84e
--- /dev/null
+++ b/configs/config_mb_2023_3_mux_2024.py
@@ -0,0 +1,133 @@
+import logging
+from ohmpi.utils import get_platform
+
+from paho.mqtt.client import MQTTv31
+
+_, on_pi = get_platform()
+# DEFINE THE ID OF YOUR OhmPi
+ohmpi_id = '0001' if on_pi else 'XXXX'
+# DEFINE YOUR MQTT BROKER (DEFAULT: 'localhost')
+mqtt_broker = 'localhost' if on_pi else 'NAME_YOUR_BROKER_WHEN_IN_SIMULATION_MODE_HERE'
+# DEFINE THE SUFFIX TO ADD TO YOUR LOGS FILES
+logging_suffix = ''
+
+# OhmPi configuration
+OHMPI_CONFIG = {
+    'id': ohmpi_id,  # Unique identifier of the OhmPi board (string)
+    'settings': 'ohmpi_settings.json',  # INSERT YOUR FAVORITE SETTINGS FILE HERE
+}
+
+HARDWARE_CONFIG = {
+    'ctl': {'model': 'raspberry_pi_i2c'},
+    'pwr': {'model': 'pwr_batt', 'voltage': 12.},
+    'tx':  {'model': 'ohmpi_card_3_15',
+             'mcp_board_address': 0x20,
+             'voltage_max': 12.,  # Maximum voltage supported by the TX board [V]
+             'current_max': 4800 / 50 / 2,  # Maximum current supported by the TX board [mA]
+             'r_shunt': 2  # Shunt resistance in Ohms
+            },
+    'rx':  {'model': 'ohmpi_card_3_15',
+             'coef_p2': 2.50,  # slope for conversion for ADS, measurement in V/V
+             'latency': 0.010,  # latency in seconds in continuous mode
+             'sampling_rate': 50  # number of samples per second
+            },
+    'mux':  # default properties are system properties that will be
+            # overwritten by board properties defined at the board level within the board model file
+            # both will be overwritten by properties specified in the board dict below. Use with caution...
+            {'boards':
+                    {'mux_1':
+                         {'model': 'mux_2024_rev_0_0',  # 'ohmpi_i2c_mux64_v1.01',
+                          'tca_address': None,
+                          'tca_channel': 0,
+                          'mcp_0': '0x22',  # TODO : Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user...
+                          'mcp_1': '0x23',  # TODO : Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user...)
+                          'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'},
+                          'cabling': {(i+8, j): ('mux_1', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)},
+                          'voltage_max': 12.},
+                     'mux_2':
+                         {'model': 'mux_2024_rev_0_0',  # 'ohmpi_i2c_mux64_v1.01',
+                          'tca_address': None,
+                          'tca_channel': 0,
+                          'mcp_0': '0x24',  # TODO : Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user...
+                          'mcp_1': '0x25',  # TODO : Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user...)
+                          'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'},
+                          'cabling': {(i+16, j): ('mux_2', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)},
+                          'voltage_max': 12.}
+                     },
+             'default': {'voltage_max': 100.,
+                         'current_max': 3.}
+             }
+}
+
+# SET THE LOGGING LEVELS, MQTT BROKERS AND MQTT OPTIONS ACCORDING TO YOUR NEEDS
+# Execution logging configuration
+EXEC_LOGGING_CONFIG = {
+    'logging_level': logging.INFO,
+    'log_file_logging_level': logging.DEBUG,
+    'logging_to_console': True,
+    'file_name': f'exec{logging_suffix}.log',
+    'max_bytes': 262144,
+    'backup_count': 30,
+    'when': 'd',
+    'interval': 1
+}
+
+# Data logging configuration
+DATA_LOGGING_CONFIG = {
+    'logging_level': logging.INFO,
+    'logging_to_console': True,
+    'file_name': f'data{logging_suffix}.log',
+    'max_bytes': 16777216,
+    'backup_count': 1024,
+    'when': 'd',
+    'interval': 1
+}
+
+# State of Health logging configuration (For a future release)
+SOH_LOGGING_CONFIG = {
+    'logging_level': logging.INFO,
+    'logging_to_console': True,
+    'log_file_logging_level': logging.DEBUG,
+    'file_name': f'soh{logging_suffix}.log',
+    'max_bytes': 16777216,
+    'backup_count': 1024,
+    'when': 'd',
+    'interval': 1
+}
+
+# MQTT logging configuration parameters
+MQTT_LOGGING_CONFIG = {
+    'hostname': mqtt_broker,
+    'port': 1883,
+    'qos': 2,
+    'retain': False,
+    'keepalive': 60,
+    'will': None,
+    'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'},
+    'tls': None,
+    'protocol': MQTTv31,
+    'transport': 'tcp',
+    'client_id': f'{OHMPI_CONFIG["id"]}',
+    'exec_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/exec',
+    'exec_logging_level': logging.DEBUG,
+    'data_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/data',
+    'data_logging_level': DATA_LOGGING_CONFIG['logging_level'],
+    'soh_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/soh',
+    'soh_logging_level': SOH_LOGGING_CONFIG['logging_level']
+}
+
+# MQTT control configuration parameters
+MQTT_CONTROL_CONFIG = {
+    'hostname': mqtt_broker,
+    'port': 1883,
+    'qos': 2,
+    'retain': False,
+    'keepalive': 60,
+    'will': None,
+    'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'},
+    'tls': None,
+    'protocol': MQTTv31,
+    'transport': 'tcp',
+    'client_id': f'{OHMPI_CONFIG["id"]}',
+    'ctrl_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/ctrl'
+}