diff --git a/configs/config_mb_2023_3_mux_2024.py b/configs/config_mb_2023_3_mux_2024.py new file mode 100644 index 0000000000000000000000000000000000000000..3b0e8cad1e2ff6f1f1387b5e20ec4ddaa58ff84e --- /dev/null +++ b/configs/config_mb_2023_3_mux_2024.py @@ -0,0 +1,133 @@ +import logging +from ohmpi.utils import get_platform + +from paho.mqtt.client import MQTTv31 + +_, on_pi = get_platform() +# DEFINE THE ID OF YOUR OhmPi +ohmpi_id = '0001' if on_pi else 'XXXX' +# DEFINE YOUR MQTT BROKER (DEFAULT: 'localhost') +mqtt_broker = 'localhost' if on_pi else 'NAME_YOUR_BROKER_WHEN_IN_SIMULATION_MODE_HERE' +# DEFINE THE SUFFIX TO ADD TO YOUR LOGS FILES +logging_suffix = '' + +# OhmPi configuration +OHMPI_CONFIG = { + 'id': ohmpi_id, # Unique identifier of the OhmPi board (string) + 'settings': 'ohmpi_settings.json', # INSERT YOUR FAVORITE SETTINGS FILE HERE +} + +HARDWARE_CONFIG = { + 'ctl': {'model': 'raspberry_pi_i2c'}, + 'pwr': {'model': 'pwr_batt', 'voltage': 12.}, + 'tx': {'model': 'ohmpi_card_3_15', + 'mcp_board_address': 0x20, + 'voltage_max': 12., # Maximum voltage supported by the TX board [V] + 'current_max': 4800 / 50 / 2, # Maximum current supported by the TX board [mA] + 'r_shunt': 2 # Shunt resistance in Ohms + }, + 'rx': {'model': 'ohmpi_card_3_15', + 'coef_p2': 2.50, # slope for conversion for ADS, measurement in V/V + 'latency': 0.010, # latency in seconds in continuous mode + 'sampling_rate': 50 # number of samples per second + }, + 'mux': # default properties are system properties that will be + # overwritten by board properties defined at the board level within the board model file + # both will be overwritten by properties specified in the board dict below. Use with caution... + {'boards': + {'mux_1': + {'model': 'mux_2024_rev_0_0', # 'ohmpi_i2c_mux64_v1.01', + 'tca_address': None, + 'tca_channel': 0, + 'mcp_0': '0x22', # TODO : Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user... + 'mcp_1': '0x23', # TODO : Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user...) + 'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'}, + 'cabling': {(i+8, j): ('mux_1', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)}, + 'voltage_max': 12.}, + 'mux_2': + {'model': 'mux_2024_rev_0_0', # 'ohmpi_i2c_mux64_v1.01', + 'tca_address': None, + 'tca_channel': 0, + 'mcp_0': '0x24', # TODO : Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user... + 'mcp_1': '0x25', # TODO : Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user...) + 'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'}, + 'cabling': {(i+16, j): ('mux_2', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)}, + 'voltage_max': 12.} + }, + 'default': {'voltage_max': 100., + 'current_max': 3.} + } +} + +# SET THE LOGGING LEVELS, MQTT BROKERS AND MQTT OPTIONS ACCORDING TO YOUR NEEDS +# Execution logging configuration +EXEC_LOGGING_CONFIG = { + 'logging_level': logging.INFO, + 'log_file_logging_level': logging.DEBUG, + 'logging_to_console': True, + 'file_name': f'exec{logging_suffix}.log', + 'max_bytes': 262144, + 'backup_count': 30, + 'when': 'd', + 'interval': 1 +} + +# Data logging configuration +DATA_LOGGING_CONFIG = { + 'logging_level': logging.INFO, + 'logging_to_console': True, + 'file_name': f'data{logging_suffix}.log', + 'max_bytes': 16777216, + 'backup_count': 1024, + 'when': 'd', + 'interval': 1 +} + +# State of Health logging configuration (For a future release) +SOH_LOGGING_CONFIG = { + 'logging_level': logging.INFO, + 'logging_to_console': True, + 'log_file_logging_level': logging.DEBUG, + 'file_name': f'soh{logging_suffix}.log', + 'max_bytes': 16777216, + 'backup_count': 1024, + 'when': 'd', + 'interval': 1 +} + +# MQTT logging configuration parameters +MQTT_LOGGING_CONFIG = { + 'hostname': mqtt_broker, + 'port': 1883, + 'qos': 2, + 'retain': False, + 'keepalive': 60, + 'will': None, + 'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'}, + 'tls': None, + 'protocol': MQTTv31, + 'transport': 'tcp', + 'client_id': f'{OHMPI_CONFIG["id"]}', + 'exec_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/exec', + 'exec_logging_level': logging.DEBUG, + 'data_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/data', + 'data_logging_level': DATA_LOGGING_CONFIG['logging_level'], + 'soh_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/soh', + 'soh_logging_level': SOH_LOGGING_CONFIG['logging_level'] +} + +# MQTT control configuration parameters +MQTT_CONTROL_CONFIG = { + 'hostname': mqtt_broker, + 'port': 1883, + 'qos': 2, + 'retain': False, + 'keepalive': 60, + 'will': None, + 'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'}, + 'tls': None, + 'protocol': MQTTv31, + 'transport': 'tcp', + 'client_id': f'{OHMPI_CONFIG["id"]}', + 'ctrl_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/ctrl' +}