From 2ef49fd79856c8ee8a1ac3467aea6aa61c06b100 Mon Sep 17 00:00:00 2001 From: Remi Clement <remi.clement@inrae.fr> Date: Mon, 25 Apr 2022 21:35:58 +0200 Subject: [PATCH] update step 4 of Ohmpi V 2.00 --- doc/source/Ohmpi_V2_00/V2_00_step_04.rst | 48 +++++++++++++++++++++++- 1 file changed, 46 insertions(+), 2 deletions(-) diff --git a/doc/source/Ohmpi_V2_00/V2_00_step_04.rst b/doc/source/Ohmpi_V2_00/V2_00_step_04.rst index 1c9fe0de..8ae9cd5a 100644 --- a/doc/source/Ohmpi_V2_00/V2_00_step_04.rst +++ b/doc/source/Ohmpi_V2_00/V2_00_step_04.rst @@ -17,11 +17,55 @@ +--------+------------------------------------------------------------+ | | .. image:: step_n_4/step_4_2.jpg | - | 1 +------------------------------------------------------------+ + | 2 +------------------------------------------------------------+ | |Crimp the ribbon cable on the corresponding idc connector | | |with a suitable clamp. Pay attention to the direction of the| | |cables. Unbalanced IDC connector. The ribbon cable must be | | |perpendicular to the connector. | +--------+------------------------------------------------------------+ - \ No newline at end of file +.. table:: + :align: center + + +--------+------------------------------------------------------------+ + | | .. image:: step_n_4/step_4_3.jpg | + | 3 +------------------------------------------------------------+ + | |Example of IDC connector mounting. The wires should run as | + | |perpendicular as possible to the IDC connector. | + +--------+------------------------------------------------------------+ + + +.. table:: + :align: center + + +--------+------------------------------------------------------------+ + | | .. image:: step_n_4/step_4_4.jpg | + | 4 +------------------------------------------------------------+ + | |Same for a 6 wires ribbon cable of 1 m length. | + | | | + +--------+------------------------------------------------------------+ + +.. table:: + :align: center + + +--------+------------------------------------------------------------+ + | | .. image:: step_n_4/step_4_5.jpg | + | 5 +------------------------------------------------------------+ + | |Cut the ribbon cable flush with the IDC connector. | + | | | + +--------+------------------------------------------------------------+ + +.. table:: + :align: center + + +--------+------------------------------------------------------------+ + | | .. image:: step_n_4/step_4_6.jpg | + | 6 +------------------------------------------------------------+ + | |Position 9 spacers above the MUX board, and 9 spacers below.| + | | | + + +------------------------------------------------------------+ + | | .. image:: step_n_4/step_4_7.jpg | + | +------------------------------------------------------------+ + | |Profile view for mounting the spacers above and below. | + | | | + +--------+------------------------------------------------------------+ \ No newline at end of file -- GitLab