diff --git a/configs/config_mb_2024_0_2__2_mux_2024_2roles_dps5005.py b/configs/config_mb_2024_0_2__2_mux_2024_2roles_dps5005.py
new file mode 100644
index 0000000000000000000000000000000000000000..9905b3fa03243d42301c49fc154bbf612ecc180d
--- /dev/null
+++ b/configs/config_mb_2024_0_2__2_mux_2024_2roles_dps5005.py
@@ -0,0 +1,129 @@
+import logging
+from ohmpi.utils import get_platform
+from paho.mqtt.client import MQTTv31  # noqa
+
+_, on_pi = get_platform()
+# DEFINE THE ID OF YOUR OhmPi
+ohmpi_id = '0001' if on_pi else 'XXXX'
+# DEFINE YOUR MQTT BROKER (DEFAULT: 'localhost')
+mqtt_broker = 'localhost' if on_pi else 'NAME_YOUR_BROKER_WHEN_IN_SIMULATION_MODE_HERE'
+# DEFINE THE SUFFIX TO ADD TO YOUR LOGS FILES
+logging_suffix = ''
+
+# OhmPi configuration
+OHMPI_CONFIG = {
+    'id': ohmpi_id,  # Unique identifier of the OhmPi board (string)
+    'settings': 'ohmpi_settings.json',  # INSERT YOUR FAVORITE SETTINGS FILE HERE
+}
+
+r_shunt = 2.
+HARDWARE_CONFIG = {
+    'ctl': {'model': 'raspberry_pi'},
+    'pwr': {'model': 'pwr_dps5005', 'voltage': 3., 'interface_name': 'modbus'},
+    'tx':  {'model': 'mb_2024_0_2',
+             'voltage_max': 50.,  # Maximum voltage supported by the TX board [V]
+             'current_max': 4.80/(50*r_shunt),  # Maximum voltage read by the current ADC on the TX board [A]
+             'r_shunt': r_shunt,  # Shunt resistance in Ohms
+             'interface_name': 'i2c'
+            },
+    'rx':  {'model': 'mb_2024_0_2',
+             'latency': 0.010,  # latency in seconds in continuous mode
+             'sampling_rate': 50,  # number of samples per second
+             'interface_name': 'i2c'
+            },
+    'mux': {'boards':
+                {'mux_06':
+                     {'model': 'mux_2024_0_X',
+                      'roles': ['A', 'B'],
+                      'electrodes': range(1, 17),
+                      'tca_address': None,
+                      'tca_channel': 0,
+                      'addr2': 'down',
+                      'addr1': 'down'},
+                 'mux_03':
+                     {'model': 'mux_2024_0_X',
+                      'roles': ['M', 'N'],
+                      'electrodes': range(1, 17),
+                      'tca_address': None,
+                      'tca_channel': 0,
+                      'addr2': 'up',
+                      'addr1': 'down'}
+                 },
+             'default': {'interface_name': 'i2c_ext',
+                         'voltage_max': 50.,
+                         'current_max': 3.}
+            }
+    }
+
+# SET THE LOGGING LEVELS, MQTT BROKERS AND MQTT OPTIONS ACCORDING TO YOUR NEEDS
+# Execution logging configuration
+EXEC_LOGGING_CONFIG = {
+    'logging_level': logging.INFO,
+    'log_file_logging_level': logging.DEBUG,
+    'logging_to_console': True,
+    'file_name': f'exec{logging_suffix}.log',
+    'max_bytes': 262144,
+    'backup_count': 30,
+    'when': 'd',
+    'interval': 1
+}
+
+# Data logging configuration
+DATA_LOGGING_CONFIG = {
+    'logging_level': logging.INFO,
+    'logging_to_console': True,
+    'file_name': f'data{logging_suffix}.log',
+    'max_bytes': 16777216,
+    'backup_count': 1024,
+    'when': 'd',
+    'interval': 1
+}
+
+# State of Health logging configuration (For a future release)
+SOH_LOGGING_CONFIG = {
+    'logging_level': logging.INFO,
+    'logging_to_console': True,
+    'log_file_logging_level': logging.DEBUG,
+    'file_name': f'soh{logging_suffix}.log',
+    'max_bytes': 16777216,
+    'backup_count': 1024,
+    'when': 'd',
+    'interval': 1
+}
+
+# MQTT logging configuration parameters
+MQTT_LOGGING_CONFIG = {
+    'hostname': mqtt_broker,
+    'port': 1883,
+    'qos': 2,
+    'retain': False,
+    'keepalive': 60,
+    'will': None,
+    'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'},
+    'tls': None,
+    'protocol': MQTTv31,
+    'transport': 'tcp',
+    'client_id': f'{OHMPI_CONFIG["id"]}',
+    'exec_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/exec',
+    'exec_logging_level': logging.DEBUG,
+    'data_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/data',
+    'data_logging_level': DATA_LOGGING_CONFIG['logging_level'],
+    'soh_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/soh',
+    'soh_logging_level': SOH_LOGGING_CONFIG['logging_level']
+}
+
+# MQTT control configuration parameters
+MQTT_CONTROL_CONFIG = {
+    'hostname': mqtt_broker,
+    'port': 1883,
+    'qos': 2,
+    'retain': False,
+    'keepalive': 60,
+    'will': None,
+    'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'},
+    'tls': None,
+    'protocol': MQTTv31,
+    'transport': 'tcp',
+    'client_id': f'{OHMPI_CONFIG["id"]}',
+    'ctrl_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/ctrl'
+}