import logging from OhmPi.utils import get_platform from paho.mqtt.client import MQTTv31 _, on_pi = get_platform() # DEFINE THE ID OF YOUR OhmPi ohmpi_id = '0001' if on_pi else 'XXXX' # DEFINE YOUR MQTT BROKER (DEFAULT: 'localhost') mqtt_broker = 'localhost' if on_pi else 'NAME_YOUR_BROKER_WHEN_IN_SIMULATION_MODE_HERE' # DEFINE THE SUFFIX TO ADD TO YOUR LOGS FILES logging_suffix = '' # OhmPi configuration OHMPI_CONFIG = { 'id': ohmpi_id, # Unique identifier of the OhmPi board (string) # 'R_shunt': 2, # Shunt resistance in Ohms # 'Imax': 4800 / 50 / 2, # Maximum current # 'coef_p2': 2.50, # slope for current conversion for ADS.P2, measurement in V/V # 'nb_samples': 20, # Max value 10 # was named integer before... # 'version': 2, # Is this still needed? # 'max_elec': 64, # 'board_addresses': {'A': 0x73, 'B': 0x72, 'M': 0x71, 'N': 0x70}, # CHECK IF YOUR BOARDS HAVE THESE ADDRESSES 'settings': 'ohmpi_settings.json', # INSERT YOUR FAVORITE SETTINGS FILE HERE # 'board_version': 'mb.2023.0.0',#,'22.10', # 'mcp_board_address': 0x20 } # TODO: add a dictionary with INA models and associated gain values HARDWARE_CONFIG = { 'controller': {'model' : 'raspberry_pi_3' }, 'tx' : {'model' : 'mb_2024_rev_0_0', 'mcp_board_address': 0x20, 'Imax': 4800 / 50 / 2, # Maximum current 'R_shunt': 2 # Shunt resistance in Ohms }, 'rx' : {'model': 'mb_2024_rev_0_0', 'coef_p2': 2.50, # slope for current conversion for ADS.P2, measurement in V/V 'nb_samples': 20, # Max value 10 # was named integer before... }, 'mux': {'model' : 'mux_2021', 'max_elec': 64, 'board_addresses': {'A': 0x73, 'B': 0x72, 'M': 0x71, 'N': 0x70}, # CHECK IF YOUR BOARDS HAVE THESE ADDRESSES 'coef_p2': 2.50, # slope for current conversion for ADS.P2, measurement in V/V 'nb_samples': 20 # Max value 10 # was named integer before... } } # SET THE LOGGING LEVELS, MQTT BROKERS AND MQTT OPTIONS ACCORDING TO YOUR NEEDS # Execution logging configuration EXEC_LOGGING_CONFIG = { 'logging_level': logging.INFO, 'log_file_logging_level': logging.DEBUG, 'logging_to_console': True, 'file_name': f'exec{logging_suffix}.log', 'max_bytes': 262144, 'backup_count': 30, 'when': 'd', 'interval': 1 } # Data logging configuration DATA_LOGGING_CONFIG = { 'logging_level': logging.INFO, 'logging_to_console': True, 'file_name': f'data{logging_suffix}.log', 'max_bytes': 16777216, 'backup_count': 1024, 'when': 'd', 'interval': 1 } # State of Health logging configuration (For a future release) SOH_LOGGING_CONFIG = { 'logging_level': logging.INFO, 'logging_to_console': True, 'file_name': f'soh{logging_suffix}.log', 'max_bytes': 16777216, 'backup_count': 1024, 'when': 'd', 'interval': 1 } # MQTT logging configuration parameters MQTT_LOGGING_CONFIG = { 'hostname': mqtt_broker, 'port': 1883, 'qos': 2, 'retain': False, 'keepalive': 60, 'will': None, 'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'}, 'tls': None, 'protocol': MQTTv31, 'transport': 'tcp', 'client_id': f'{OHMPI_CONFIG["id"]}', 'exec_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/exec', 'exec_logging_level': logging.DEBUG, 'data_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/data', 'data_logging_level': DATA_LOGGING_CONFIG['logging_level'], 'soh_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/soh', 'soh_logging_level': SOH_LOGGING_CONFIG['logging_level'] } # MQTT control configuration parameters MQTT_CONTROL_CONFIG = { 'hostname': mqtt_broker, 'port': 1883, 'qos': 2, 'retain': False, 'keepalive': 60, 'will': None, 'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'}, 'tls': None, 'protocol': MQTTv31, 'transport': 'tcp', 'client_id': f'{OHMPI_CONFIG["id"]}', 'ctrl_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/ctrl' }