diff --git a/doc/source/1_Datalogger_SETIER_physico-chemical_EN.rst b/doc/source/1_Datalogger_SETIER_physico-chemical_EN.rst index c6052b563ee0360b0b24ed6557157026b9eb3d47..d292d51f7792be92724da0813b2592a1a839aa19 100644 --- a/doc/source/1_Datalogger_SETIER_physico-chemical_EN.rst +++ b/doc/source/1_Datalogger_SETIER_physico-chemical_EN.rst @@ -812,7 +812,7 @@ Material List :alt: alternate text :figclass: align-center -#. Set the "**ORP sensor**" wire inside the cable gland (from outside to inside the box), then, screw them on the screw terminal block. +#. Set the "**ORP sensor**" wire inside the cable gland (from outside to inside the box), then, screw them on the screw terminal block. ** caution: the blue and red cables must not touch each other as this could damage the sensor.** .. figure:: Image/Physico_Chemical/Hardware/ORP_sensor_screw.JPG :width: 900px diff --git a/doc/source/2_Datalogger_SETIER_physico-chimique_FR.rst b/doc/source/2_Datalogger_SETIER_physico-chimique_FR.rst index 8816549d2b04a3afdae15c9c6afae124385e559b..0d42b82e2966eb1cdd3ba75b7645dab3f6d0021f 100644 --- a/doc/source/2_Datalogger_SETIER_physico-chimique_FR.rst +++ b/doc/source/2_Datalogger_SETIER_physico-chimique_FR.rst @@ -813,7 +813,7 @@ Liste du matériel :alt: alternate text :figclass: align-center -#. Faire passer les cables du capteur "**ORP**" dans le presse-étoupe (de l'extérieur vers l'intérieur), puis visser ces cables sur le bornier à vis (voir image), puis connecter le bornier à vis sur la carte du capteur ORP. +#. Faire passer les cables du capteur "**ORP**" dans le presse-étoupe (de l'extérieur vers l'intérieur), puis visser ces cables sur le bornier à vis (voir image), puis connecter le bornier à vis sur la carte du capteur ORP. **Attention, les cables rouge et bleu ne doivent en aucun se toucher, sous risque de détériorer fortement le capteur.** .. figure:: Image/Physico_Chemical/Hardware/ORP_sensor_screw.JPG :width: 900px