......@@ -75,6 +75,7 @@ RunModel_Lag <- function(InputsModel, RunOptions, Param) {
rep(0, floor(PT[x] + 1))
})
}
#message("Initstates: ",paste(IniStates, collapse = ", "))
for (upstream_basin in seq_len(NbUpBasins)) {
Qupstream <- InputsModel$Qupstream[RunOptions$IndPeriod_Run, upstream_basin]
......@@ -85,6 +86,9 @@ RunModel_Lag <- function(InputsModel, RunOptions, Param) {
Qupstream1 <- c(IniStates[[upstream_basin]][-length(IniStates[[upstream_basin]])], Qupstream[1:(LengthTs - floor(PT[upstream_basin]))])
Qupstream2 <- IniStates[[upstream_basin]]
if(LengthTs - floor(PT[upstream_basin]) - 1 > 0) Qupstream2 <- c(Qupstream2, Qupstream[1:(LengthTs - floor(PT[upstream_basin]) - 1)])
#message("Qupstream1: ", paste(Qupstream1, collapse = ", "))
#message("Qupstream2: ", paste(Qupstream2, collapse = ", "))
OutputsModel$Qsim <- OutputsModel$Qsim +
Qupstream1 * HUTRANS[1, upstream_basin] +
Qupstream2 * HUTRANS[2, upstream_basin]
......@@ -96,12 +100,19 @@ RunModel_Lag <- function(InputsModel, RunOptions, Param) {
}
# Convert back Qsim to mm
OutputsModel$Qsim <- OutputsModel$Qsim / sum(InputsModel$BasinAreas, na.rm = TRUE) / 1e3
#message("Qsim: ",paste(OutputsModel$Qsim, collapse = ", "))
if ("StateEnd" %in% RunOptions$Outputs_Sim) {
OutputsModel$StateEnd$SD <- lapply(seq(NbUpBasins), function(x) {
LengthTs <- tail(RunOptions$IndPeriod_Run,1)
InputsModel$Qupstream[(LengthTs - floor(PT[x])):LengthTs, x]
Qupstream <- InputsModel$Qupstream[(LengthTs - floor(PT[x])):LengthTs, x]
if (!is.na(InputsModel$BasinAreas[x])) {
# Upstream flow with area needs to be converted to m3 by time step
Qupstream <- Qupstream * InputsModel$BasinAreas[x] * 1e3
}
return(Qupstream)
})
#message("StateEnd: ",paste(OutputsModel$StateEnd$SD, collapse = ", "))
}
return(OutputsModel)
......
......@@ -17,8 +17,9 @@ test_that("RunModelSupervisor with no regulation should returns same results as
Qobs <- cbind(sapply(Severn$BasinsObs, function(x) {x$discharge_spec}))
InputsModel <- CreateInputsModel(griwrm, DatesR, Precip, PotEvap, Qobs)
# RunOptions
nTS <- 365
IndPeriod_Run <- seq(
length(InputsModel[[1]]$DatesR) - 365,
length(InputsModel[[1]]$DatesR) - nTS + 1,
length(InputsModel[[1]]$DatesR)
)
IndPeriod_WarmUp = seq(IndPeriod_Run[1]-366,IndPeriod_Run[1]-1)
......