RunModel.Supervision: add option to choose period of supervision (including warm-up period)
Running management model can be necessary during warm-up period for example to get a correct initialisation of a reservoir volume (Thanks @myriam.soutif-bellenger).
I propose to add a new argument on the CreateRunOptions.GRiwrmInputsModel
function:
IndPeriod_Supervision = IndPeriod_Run
- by default, it will acts as the current version
- it allows the user to run the supervision on desired time steps even non-contiguous time steps
- an argument
IndPeriod_Supervision = c(IndPeriod_WarmUp, IndPeriod_Run)
would solve the issue raised by Myriam