Newer
Older
Olivier Kaufmann
committed
from utils import get_platform
Olivier Kaufmann
committed
_, on_pi = get_platform()
# DEFINE THE ID OF YOUR OhmPi
ohmpi_id = '0001' if on_pi else 'XXXX'
# DEFINE YOUR MQTT BROKER (DEFAULT: 'localhost')
mqtt_broker = 'localhost' if on_pi else 'NAME_YOUR_BROKER_WHEN_IN_SIMULATION_MODE_HERE'
# DEFINE THE SUFFIX TO ADD TO YOUR LOGS FILES
Olivier Kaufmann
committed
logging_suffix = ''
# OhmPi configuration
OHMPI_CONFIG = {
Olivier Kaufmann
committed
'id': ohmpi_id, # Unique identifier of the OhmPi board (string)
'R_shunt': 2, # Shunt resistance in Ohms
Olivier Kaufmann
committed
'Imax': 4800 / 50 / 2, # Maximum current
'coef_p2': 2.50, # slope for current conversion for ADS.P2, measurement in V/V
Olivier Kaufmann
committed
'version': 2, # Is this still needed?
'board_addresses': {'A': 0x73, 'B': 0x72, 'M': 0x71, 'N': 0x70}, # CHECK IF YOUR BOARDS HAVE THESE ADDRESSES
'settings': 'ohmpi_settings.json', # INSERT YOUR FAVORITE SETTINGS FILE HERE
'board_version': 'mb.2023.0.0',#,'22.10',
'mcp_board_address': 0x20,
'i2c_mux_address': 2 # 2 if on same bus as the measurement board, 4 if additional bus
} # TODO: add a dictionary with INA models and associated gain values
# SET THE LOGGING LEVELS, MQTT BROKERS AND MQTT OPTIONS ACCORDING TO YOUR NEEDS
# Execution logging configuration
EXEC_LOGGING_CONFIG = {
Olivier Kaufmann
committed
'logging_level': logging.INFO,
Olivier Kaufmann
committed
'log_file_logging_level': logging.DEBUG,
'file_name': f'exec{logging_suffix}.log',
'max_bytes': 262144,
'backup_count': 30,
'when': 'd',
'interval': 1
}
# Data logging configuration
DATA_LOGGING_CONFIG = {
'logging_level': logging.INFO,
'logging_to_console': True,
'file_name': f'data{logging_suffix}.log',
'max_bytes': 16777216,
'backup_count': 1024,
'when': 'd',
'interval': 1
}
# State of Health logging configuration (For a future release)
'max_bytes': 16777216,
'backup_count': 1024,
'when': 'd',
'interval': 1
}
# MQTT logging configuration parameters
MQTT_LOGGING_CONFIG = {
'port': 1883,
'qos': 2,
'retain': False,
'keepalive': 60,
'will': None,
Olivier Kaufmann
committed
'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'},
'tls': None,
'protocol': MQTTv31,
'transport': 'tcp',
'client_id': f'{OHMPI_CONFIG["id"]}',
'exec_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/exec',
'data_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/data',
'data_logging_level': DATA_LOGGING_CONFIG['logging_level'],
'soh_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/soh',
'soh_logging_level': SOH_LOGGING_CONFIG['logging_level']
}
# MQTT control configuration parameters
MQTT_CONTROL_CONFIG = {
'port': 1883,
'qos': 2,
'retain': False,
'keepalive': 60,
'will': None,
Olivier Kaufmann
committed
'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'},
'tls': None,
'protocol': MQTTv31,
'transport': 'tcp',
'client_id': f'{OHMPI_CONFIG["id"]}',
'ctrl_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/ctrl'
}