99
import logging
from utils import get_platform
from paho.mqtt.client import MQTTv31
_, on_pi = get_platform()
ohmpi_id = '0001'
# mqtt_broker = 'localhost'
mqtt_broker = 'localhost' if on_pi else 'mg3d-dev.umons.ac.be'
logging_suffix = ''
# OhmPi configuration
OHMPI_CONFIG = {
'id': ohmpi_id, # Unique identifier of the OhmPi board (string)
'R_shunt': 2, # Shunt resistance in Ohms
'Imax': 4800 / 50 / 2, # Maximum current
'coef_p2': 2.50, # slope for current conversion for ADS.P2, measurement in V/V
# 'coef_p3': 2.50, # slope for current conversion for ADS.P3, measurement in V/V
# 'offset_p2': 0,
# 'offset_p3': 0,
'nb_samples': 2, # Max value 10 # was named integer before...
'version': 2, # Is this still needed?
'max_elec': 64,
'board_addresses': {'A': 0x73, 'B': 0x72, 'M': 0x71, 'N': 0x70},
# def. {'A': 0x76, 'B': 0x71, 'M': 0x74, 'N': 0x70}
'settings': 'ohmpi_settings.json',
'board_version': '22.10'
} # TODO: add a dictionary with INA models and associated gain values
# Execution logging configuration
EXEC_LOGGING_CONFIG = {
'logging_level': logging.INFO,
'log_file_logging_level': logging.DEBUG,
'logging_to_console': True,
'file_name': f'exec{logging_suffix}.log',
'max_bytes': 262144,
'backup_count': 30,
'when': 'd',
'interval': 1
}
# Data logging configuration
DATA_LOGGING_CONFIG = {
'logging_level': logging.INFO,
'logging_to_console': True,
'file_name': f'data{logging_suffix}.log',
'max_bytes': 16777216,
'backup_count': 1024,
'when': 'd',
'interval': 1
}
# State of Health logging configuration
SOH_LOGGING_CONFIG = {
'logging_level' : logging.INFO,
'logging_to_console': True,
'file_name': 'soh.log',
'max_bytes': 16777216,
'backup_count': 1024,
'when': 'd',
'interval': 1
}
# MQTT logging configuration parameters
MQTT_LOGGING_CONFIG = {
'hostname': mqtt_broker,
'port': 1883,
'qos': 2,
'retain': False,
'keepalive': 60,
'will': None,
'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'},
'tls': None,
'protocol': MQTTv31,
'transport': 'tcp',
'client_id': f'{OHMPI_CONFIG["id"]}',
'exec_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/exec',
'exec_logging_level': logging.DEBUG,
'data_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/data',
'data_logging_level': DATA_LOGGING_CONFIG['logging_level'],
'soh_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/soh',
'soh_logging_level': SOH_LOGGING_CONFIG['logging_level']
}
# MQTT control configuration parameters
MQTT_CONTROL_CONFIG = {
'hostname': mqtt_broker,
'port': 1883,
'qos': 2,
'retain': False,
'keepalive': 60,
'will': None,
'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'},
'tls': None,
'protocol': MQTTv31,
'transport': 'tcp',
'client_id': f'{OHMPI_CONFIG["id"]}',
'ctrl_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/ctrl'
}