Updates config_mb2023_0_2__3_mux_2024_dps

Showing with 180 additions and 29 deletions
+180 -29
......@@ -19,7 +19,7 @@ OHMPI_CONFIG = {
HARDWARE_CONFIG = {
'ctl': {'model': 'raspberry_pi'},
'pwr': {'model': 'pwr_batt', 'voltage': 12.},
'pwr': {'model': 'pwr_batt', 'voltage': 12.,'interface_name':'none'},
'tx': {'model': 'mb_2023_0_X',
'voltage_max': 12., # Maximum voltage supported by the TX board [V]
'adc_voltage_max': 4800., # Maximum voltage read by the current ADC on the TX board [mA]
......@@ -36,34 +36,38 @@ HARDWARE_CONFIG = {
# if defined in board specs, values out of specs will be bounded to remain in specs
# omitted properties in config will be set to board specs default values if they exist
{'boards':
{'mux_02':
{'model': 'mux_2024_0_X',
'tca_address': None,
'tca_channel': 0,
'mcp_0': '0x22', # TODO: Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user...)
'mcp_1': '0x23', # TODO: Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user...)
'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'},
'cabling': {(i+8, j): ('mux_02', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)},
'voltage_max': 12.},
'mux_00':
{'model': 'mux_2024_0_X',
'tca_address': None,
'tca_channel': 0,
'mcp_0': '0x24', # TODO : Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user...)
'mcp_1': '0x25', # TODO : Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user...)
'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'},
'cabling': {(i+16, j): ('mux_00', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)},
'voltage_max': 12.},
'mux_04':
{'model': 'mux_2024_0_X',
'tca_address': None,
'tca_channel': 0,
'mcp_0': '0x26', # TODO : Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user...
'mcp_1': '0x27', # TODO : Replace this with pos of jumper on MUX board (address doesn't mean anything for the average user...)
'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'},
'cabling': {(i+24, j): ('mux_04', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)},
'voltage_max': 12.}
},
{'mux_02':
{'model': 'mux_2024_0_X',
'tca_address': None,
'tca_channel': 0,
'addr2': 'up',
'addr1': 'up',
# 'mcp_0': '0x26',
# 'mcp_1': '0x27',
'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'},
'cabling': {(i + 8, j): ('mux_02', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)},
'voltage_max': 50.},
'mux_03':
{'model': 'mux_2024_0_X',
'tca_address': None,
'tca_channel': 0,
'addr2': 'down',
'addr1': 'up',
# 'mcp_0': '0x26',
# 'mcp_1': '0x27',
'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'},
'cabling': {(i + 16, j): ('mux_03', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)},
'voltage_max': 50.},
'mux_05':
{'model': 'mux_2024_0_X',
'tca_address': None,
'tca_channel': 0,
'addr2': 'up',
'addr1': 'down',
'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'},
'cabling': {(i + 0, j): ('mux_05', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)},
'voltage_max': 50.},
},
'default': {'interface_name': 'i2c',
'voltage_max': 100.,
'current_max': 3.}
......
import logging
from ohmpi.utils import get_platform
from paho.mqtt.client import MQTTv31 # noqa
_, on_pi = get_platform()
# DEFINE THE ID OF YOUR OhmPi
ohmpi_id = '0001' if on_pi else 'XXXX'
# DEFINE YOUR MQTT BROKER (DEFAULT: 'localhost')
mqtt_broker = 'localhost' if on_pi else 'NAME_YOUR_BROKER_WHEN_IN_SIMULATION_MODE_HERE'
# DEFINE THE SUFFIX TO ADD TO YOUR LOGS FILES
logging_suffix = ''
# OhmPi configuration
OHMPI_CONFIG = {
'id': ohmpi_id, # Unique identifier of the OhmPi board (string)
'settings': 'ohmpi_settings.json', # INSERT YOUR FAVORITE SETTINGS FILE HERE
}
HARDWARE_CONFIG = {
'ctl': {'model': 'raspberry_pi'},
'pwr': {'model': 'pwr_batt', 'voltage': 12., 'interface_name': 'none'},
'tx': {'model': 'mb_2023_0_X',
'voltage_max': 12., # Maximum voltage supported by the TX board [V]
'adc_voltage_max': 4800., # Maximum voltage read by the current ADC on the TX board [mA]
'r_shunt': 2., # Shunt resistance in Ohms
'interface_name': 'i2c',
},
'rx': {'model': 'mb_2023_0_X',
'coef_p2': 2.50, # slope for conversion for ADS, measurement in V/V
'sampling_rate': 50., # number of samples per second
'interface_name': 'i2c',
},
'mux': # default properties given in config are system properties that will be
# overwritten by properties defined in each the board dict below.
# if defined in board specs, values out of specs will be bounded to remain in specs
# omitted properties in config will be set to board specs default values if they exist
{'boards': {'mux_02':
{'model': 'mux_2024_0_X',
'tca_address': None,
'tca_channel': 0,
'addr2': 'up',
'addr1': 'up',
# 'mcp_0': '0x26',
# 'mcp_1': '0x27',
'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'},
'cabling': {(i+8, j): ('mux_02', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)},
'voltage_max': 50.},
'mux_03':
{'model': 'mux_2024_0_X',
'tca_address': None,
'tca_channel': 0,
'addr2': 'down',
'addr1': 'up',
# 'mcp_0': '0x26',
# 'mcp_1': '0x27',
'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'},
'cabling': {(i+16, j): ('mux_03', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)},
'voltage_max': 50.},
'mux_05':
{'model': 'mux_2024_0_X',
'tca_address': None,
'tca_channel': 0,
'addr2': 'up',
'addr1': 'down',
'roles': {'A': 'X', 'B': 'Y', 'M': 'XX', 'N': 'YY'},
'cabling': {(i+0, j): ('mux_05', i) for j in ['A', 'B', 'M', 'N'] for i in range(1, 9)},
'voltage_max': 50.},
},
'default': {'interface_name': 'i2c',
'voltage_max': 100.,
'current_max': 3.}
}
}
# SET THE LOGGING LEVELS, MQTT BROKERS AND MQTT OPTIONS ACCORDING TO YOUR NEEDS
# Execution logging configuration
EXEC_LOGGING_CONFIG = {
'logging_level': logging.DEBUG, # TODO: set logging level back to INFO
'log_file_logging_level': logging.DEBUG,
'logging_to_console': True,
'file_name': f'exec{logging_suffix}.log',
'max_bytes': 262144,
'backup_count': 30,
'when': 'd',
'interval': 1
}
# Data logging configuration
DATA_LOGGING_CONFIG = {
'logging_level': logging.INFO,
'logging_to_console': True,
'file_name': f'data{logging_suffix}.log',
'max_bytes': 16777216,
'backup_count': 1024,
'when': 'd',
'interval': 1
}
# State of Health logging configuration (For a future release)
SOH_LOGGING_CONFIG = {
'logging_level': logging.INFO,
'logging_to_console': True,
'log_file_logging_level': logging.DEBUG,
'file_name': f'soh{logging_suffix}.log',
'max_bytes': 16777216,
'backup_count': 1024,
'when': 'd',
'interval': 1
}
# MQTT logging configuration parameters
MQTT_LOGGING_CONFIG = {
'hostname': mqtt_broker,
'port': 1883,
'qos': 2,
'retain': False,
'keepalive': 60,
'will': None,
'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'},
'tls': None,
'protocol': MQTTv31,
'transport': 'tcp',
'client_id': f'{OHMPI_CONFIG["id"]}',
'exec_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/exec',
'exec_logging_level': logging.DEBUG,
'data_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/data',
'data_logging_level': DATA_LOGGING_CONFIG['logging_level'],
'soh_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/soh',
'soh_logging_level': SOH_LOGGING_CONFIG['logging_level']
}
# MQTT control configuration parameters
MQTT_CONTROL_CONFIG = {
'hostname': mqtt_broker,
'port': 1883,
'qos': 2,
'retain': False,
'keepalive': 60,
'will': None,
'auth': {'username': 'mqtt_user', 'password': 'mqtt_password'},
'tls': None,
'protocol': MQTTv31,
'transport': 'tcp',
'client_id': f'{OHMPI_CONFIG["id"]}',
'ctrl_topic': f'ohmpi_{OHMPI_CONFIG["id"]}/ctrl'
}
Supports Markdown