Commit 7bd5322b authored by Clement Remi's avatar Clement Remi
Browse files

Update coefficient for bridge divider

Showing with 4 additions and 4 deletions
+4 -4
......@@ -37,10 +37,10 @@ stack= 1 # repetition of the current injection for each quadripole
hardware parameters
"""
R_ref = 50 # reference resistance value in ohm
coef_p0 = 2.02 # slope for current conversion for ADS.P0, measurement in V/V
coef_p1 = 2.02 # slope for current conversion for ADS.P1, measurement in V/V
coef_p2 = 1 # slope for current conversion for ADS.P2, measurement in V/V
coef_p3 = 1 # slope for current conversion for ADS.P3, measurement in V/V
coef_p0 = 2.5 # slope for current conversion for ADS.P0, measurement in V/V
coef_p1 = 2.5 # slope for current conversion for ADS.P1, measurement in V/V
coef_p2 = 2.5 # slope for current conversion for ADS.P2, measurement in V/V
coef_p3 = 2.5 # slope for current conversion for ADS.P3, measurement in V/V
export_path = "~/measurement.csv"
"""
......
Supports Markdown
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment