...@@ -165,10 +165,9 @@ For the A electrode board, we suggest addressing it with address 0x70: ...@@ -165,10 +165,9 @@ For the A electrode board, we suggest addressing it with address 0x70:
| |Zoom on the jumper | | |Zoom on the jumper |
| | | | | |
+--------+------------------------------------------------------------+ +--------+------------------------------------------------------------+
For the B electrode board, we suggest addressing it with address 0x71: For the B electrode board, we suggest addressing it with address 0x71:
...@@ -223,7 +222,7 @@ For the M electrode board, we suggest addressing it with address 0x73: ...@@ -223,7 +222,7 @@ For the M electrode board, we suggest addressing it with address 0x73:
**PART C** Validation of MUX board **PART C** Validation of MUX board
====================================================== ======================================================
the first step is to test the Mux boards before assembling them definitively. The first step is to test the Mux boards before assembling them definitively.
To test the Mux boards, it will be necessary first to make a simplified assembly of the Mux board and the measurement board. To test the Mux boards, it will be necessary first to make a simplified assembly of the Mux board and the measurement board.
The first thing to do is to prepare a 50 cm long flat wire with two 6-poles connectors. The first thing to do is to prepare a 50 cm long flat wire with two 6-poles connectors.
...@@ -261,12 +260,16 @@ The first thing to do is to prepare a 50 cm long flat wire with two 6-poles conn ...@@ -261,12 +260,16 @@ The first thing to do is to prepare a 50 cm long flat wire with two 6-poles conn
+--------+------------------------------------------------------------+ +--------+------------------------------------------------------------+
| | .. image:: step_n_3/c/20220124_143823.jpg | | | .. image:: step_n_3/c/20220124_143823.jpg |
| 5 +------------------------------------------------------------+ | 5 +------------------------------------------------------------+
| |Connecter le cable 6 contacts | | |Connect the 6-contact cable |
| | | | | |
+--------+------------------------------------------------------------+ +--------+------------------------------------------------------------+
Démarré votre alimentation Start your 12V power supply, the raspberry must start. You can now open the script called test_mux_board.py